15815509278
  • image of OPTIC LENS>06A2D
  • image of OPTIC LENS>06A2D
06A2D
MODULE
SINGLE 250V 6A
-
-
image of OPTIC LENS>06A2D
image of OPTIC LENS>06A2D
06A2D
06A2D
MODULE
SINGLE 250V 6A
-
YES
-
9-5
1. Designed to meet globally accepted IEC publication 320 Class 1, that
allows users to comply with industry standard in power entry requirement.
o
2. Connector for cold condition, with pin temperature 70 C max.
3. Nickel-plated brass pins and soldering terminals.
4. Snap-in mount (panel thickness: 0.04 inch to 0.07 inch).
5. Power module in plastic or metal case that incorporates an IEC
connector, fuse holder, power switch and voltage selector switch, all-in-one
easy-to-install unit.
Part numbers 06A1, 06A2, 06A2D and 06A5 are power modules in plastic
case; part numbers 06AN2, 06AN2D, 06AN3, 06AN3D and 06AN5 are
power modules in metal case.
6. Fuse holder designed for one fuse. Safety interlock prevents fuse removal
with line plug inserted.
7. Adapts to 110V or 220V input voltage with voltage selector switch.
8. Compact design and high volume production provide maximum flexibility
and significant savings in space and cost over assembly of individual
components.
9. All part numbers are UL recognized, CSA certified and SEMKO approved.
1. Rated voltage: 115VAC/250VAC
2. Maximum leakage current each line-to-ground
2uA AT 115VAC/60Hz
5uA AT 250VAC/50Hz
3. Dielectric strength (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
4. Flammability class: UL 94V-0
FIG. A
FIG. C
FIG. B
FIG. D
L
N
E
N
N
G
E
L
L
I
F
A
D
SW
L
O
N
G
N
G
06AN3 ONLY
L
L
L
G
N
N
E
I
L
F
O
A
D
L
N
G
N
G
I
L
L
PRIMARIES
06AN3D ONLY
N
E
F
L
I
A
N
G
D
SW
L
L
O
D
G
N
O
A
F
L
L
TRANSFORMER
CUSTOMER
220V
110V
220V
110V
110V
SW
110V
110V
110V
ELECTRICAL SCHEMATIC
VOLTAGE SELECTOR
FUSE HOLDER
POWER SWITCH
CONNECTOR TYPE
RATED CURRENT
FEMALE
MALE
SEMKO
UL/CSA (115VAC/250VAC)
FRONT *3
FIG. B
FIG. C
FIG. D
FIG. D
FIG. C
6A
-
-
SP*1
S
S
S
S S
DP *2
DP *2
SP *1
REAR*4
REAR*4
-
06AN2
DELTA PART NUMBER 06AN3 06AN3D
06AN2D
06AN5
REMARKS:
UL/CSA/VDE APPROVED AT 10A/125VAC&
4. VOLTAGE SELECTOR SWITCH (REAR)
MAXIMUM IN-RUSH CURRENT: 50A
ELECTRICAL LIFETIME: 10,000 CYCLES
2. DOUBLE-POLE POWER SWITCH
MAXIMUM IN-RUSH CURRENT: 70A
ELECTRICAL LIFETIME: 50,000 CYCLES
VDE APPROVED AT 6A/250VAC
UL/CSA APPROVED AT 6A, 125VAC/250VAC
1. SINGLE-POLE POWER SWITCH
3. VOLTAGE SELECTOR SWITCH (FRONT)
UL/CSA APPROVED AT 6A, 125VAC/250VAC
VDE APPROVED AT 6A/250VAC
5A/250VAC
*
*
*
*
4A
6A
6A
SNAP-IN
MOUNTING
SPECIFICATIONS
INTRODUCTIONS
ELECTRICAL SCHEMATIC
VOLTAGE SELECTOR
FUSE HOLDER
POWER SWITCH
CONNECTOR TYPE
RATED CURRENT
FEMALE
MALE
SEMKO
UL/CSA (115VAC/250VAC)
FRONT *3
FIG. B
FIG. D
FIG. C
FIG. A
4A
-
-
-
-
S
S
S
S
SP *1
DP *2
6A
6A
-
6A
06A1
DELTA PART NUMBER
06A2D
06A2
06A5
*
*
*
REMARKS:
UL/CSA APPROVED AT 6A/125VAC & 250VAC
MAXIMUM IN-RUSH CURRENT: 50A
ELECTRICAL LIFETIME: 10,000 CYCLES
MAXIMUM IN-RUSH CURRENT: 70A
ELECTRICAL LIFETIME: 50,000 CYCLES
UL/CSA APPROVED AT 6A, 125VAC/250VAC
VDE APPROVED AT 6A/250VAC
3. VOLTAGE SELECTOR SWITCH
2. DOUBLE-POLE POWER SWITCH
VDE APPROVED AT 6A/250VAC
1. SINGLE-POLE POWER SWITCH
TYPE & RATED CURRENT
ELECTRICAL SCHEMATIC
POWER ENTRY MODULES
MECHANICAL CONSTRUCTION
06A5
06A1(Without voltage selector switch)
06A2
06A2D
1.059MAX.
26.9MAX.
1.32MAX.
36.0MAX.
1.417MAX.
0.28
33.5MAX.
7.0
1.15
29.2
L
N
2.65
67.3
26.9MAX.
1.059MAX.
34.0MAX.
1.34MAX.
39.5MAX.
1.555MAX.
7.0
0.28
L
N
I
O
L
N
1.063 0.003
66.0 0.08
2.6 0.003
27.0 0.08
R1.0MAX.
R0.04MAX.
INCH
mm
UNIT:
9-6
SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM FRONT)
2.65
67.3
1.15
29.2
I
O
2.65
67.3
1.15
29.2
34.0MAX.
1.34MAX.
39.5MAX.
1.555MAX.
7.0
0.28
26.9MAX.
1.059MAX.
MECHANICAL CONSTRUCTION
POWER ENTRY MODULES
06AN2
06AN2D
2.57
65.2
1.059MAX.
26.9MAX.
67.3
46.0
40.5
1.59
1.81
29.2
1.15
2.65
I
O
06AN3
06AN3D
06AN5
9-7
65.2
2.57
49.5
1.95
1.15
29.2
I
O
67.3
2.65
46.0
40.5
1.59
1.81
1.059MAX.
26.9MAX.
UNIT:
INCH
mm
65.2
2.57
29.2
1.15
67.3
2.65
Single and double-pole power
on/off switches are reversed in position.
The "0" "1" marking of
27.0 0.08
40.5
1.59
43.4
1.71
1.063 0.003
66.0 0.058
2.60 0.003
R1.0MAX.(2X)
R0.04MAX.(2X)
SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM FRONT)
1.059MAX.
26.9MAX.
MECHANICAL CONSTRUCTION
POWER ENTRY MODULES
captcha

+86-13662622177

helen@icsouls.com
0